531
Configuration error
The stored system configuration does not match the installed components, for example after a component was swapped or the wrong software variant was installed for the bike model. This cannot be fixed at the roadside: the dealer has to correct the configuration with the Bosch diagnostic software.
- Drive system
- Bosch eBike Systems
- Category
- System / software
- Motor behavior
- behavior unclear
- DIY-friendly?
- shop recommended
Roadside self-help
- Restart the system
- If the error persists, have the configuration corrected by a Bosch dealer
Possible causes
- Component replaced without reconfiguration medium
- Wrong software variant for the bike model medium
- Incompatible component installed medium
Symptoms
- Error 531 on the display
- Error typically appears after a repair or component swap
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- dealer diagnostic tool required
- Component: system configuration
- Component: drive unit
- Component: on board computer